Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Arq. Asma, Alerg. Imunol ; 7(1): 103-108, 20230300. ilus
Artigo em Inglês | LILACS | ID: biblio-1509637

RESUMO

Introduction: Montelukast, a selective and active leukotriene receptor antagonist, is one of the most common agents in asthma treatment for both adults and children. Objective: To assess whether the pharmacokinetic profiles of two formulations of montelukast were similar after a single 5 mg dose (chewable tablets), administered orally under fasting conditions, sampling blood before and 36 hours after administration. Methods: This was a randomized, 2-sequence, 2-period, crossover study of 2 chewable tablet formulations of the drug: Singulair®, provided by Merck Sharp and Dohme Farmacêutica Ltda. (reference), and generic montelukast, manufactured by Eurofarma Laboratórios S.A. (test). Plasma samples obtained from 35 participants were analyzed for montelukast through high-performance liquid chromatography coupled to tandem mass spectrometry, with montelukast-d6 as the internal standard. Peak montelukast concentrations were 299.313 (SD, 11.039) ng/mL for the reference formulation and 279.803 (SD, 10.085) ng/mL for test formulation. Results: Statistical analysis showed no significant differences between AUC0-36h, AUC0-inf, or Cmax between formulations, with the following test/reference ratios: 102.458 for AUC0-36h, 102.522 for AUC0-inf, and 93.490 for Cmax. No serious adverse events were reported during the trial. Our results demonstrated the bioequivalence of Singulair® and Eurofarma's generic montelukast. Conclusions: Our results revealed that the new generic tablets are clinically safe and can be used interchangeably with the brand name product. Eurofarma's montelukast offers a safe, effective, and cheaper treatment option for people with asthma or allergic rhinitis.


Introdução: O montelucaste, um antagonista seletivo e ativo dos receptores de leucotrienos, é um dos agentes mais comumente usados na prática clínica no tratamento da asma, tanto em adultos quanto em crianças. Objetivo: Avaliar se os perfis farmacocinéticos de duas formulações de montelucaste eram semelhantes após uma dose única de comprimidos mastigáveis de 5 mg, administrados por via oral em jejum, coletando amostras de sangue desde antes da administração até 36 horas depois disso. Métodos: Estudo comparativo randomizado, 2 sequências e 2 períodos, cruzado, de dois medicamentos em comprimidos mastigáveis: Singulair®, fornecido pela Merck Sharp e Dohme Farmacêutica Ltda. (referência) e Montelucaste 5 mg, fabricado pela Eurofarma Laboratórios S.A. (teste). Amostras de plasma obtidas de 35 indivíduos elegíveis foram analisadas para montelucaste por cromatografia líquida de alta eficiência acoplada a espectrometria de massa em tandem, tendo Montelucaste-d6 como padrão interno. As concentrações máximas de montelucaste foram 299,313±11,039 ng/mL para referência e 279,803±10,085 ng/mL para formulação de teste. Resultados: A análise estatística não mostrou diferenças significativas para AUC0-36h, AUC0-inf e nem para Cmax entre as formulações, apresentando as razões Teste/Referência: 102,458 para AUC0-36h, 102,522 para AUC0-inf e 93,490 para Cmax. Nenhum evento adverso grave foi relatado durante o estudo. De acordo com a regulamentação brasileira, o atual estudo farmacocinético demonstrou bioequivalência entre os agentes individuais e forneceu evidências de bioequivalência entre Singulair® e Montelukast fabricado pela Eurofarma. Resultado: Os resultados mostraram que os novos comprimidos genéricos são clinicamente seguros e podem ser trocados pela marca original. O montelucaste da Eurofarma oferece uma opção de tratamento mais barata, segura e eficaz para indivíduos com asma ou rinite alérgica.


Assuntos
Humanos , Adolescente , Adulto , Pessoa de Meia-Idade
2.
Rev. Bras. Cancerol. (Online) ; 69(4): e-154060, out-dez. 2023.
Artigo em Inglês | LILACS, Sec. Est. Saúde SP | ID: biblio-1526065

RESUMO

Introduction: Imatinib mesylate is currently the first-line oral treatment for all stages of chronic myeloid leukemia (CML) and is also used in some cases of gastrointestinal stromal tumor (GIST) and acute lymphoblastic leukemia (ALL). Objective: Investigate the bioavailability of two products containing imatinib mesylate, 100 mg coated tablet, to determine if they are bioequivalent. Method: The study was conducted using an open-label, randomized, balanced design and the formulations were administered orally in a single dose to 48 healthy adult males, in fed state, followed by sequential blood withdraws for the next 72 hours. Forty-eight male healthy volunteers were selected to participate in the study. Test formulation from Eurofarma Laboratórios S.A. Brazil was compared to from Novartis Biociências S.A. The comparative bioavailability of the formulations was assessed based on statistical comparisons of relevant pharmacokinetic parameters obtained from drug concentration data from collected blood samples measured using an analytical method based on high-performance liquid chromatography coupled to mass spectrometry. Results: The ratio of the geometric means between the test and the reference, with a 90% confidence interval, of pharmacokinetic parameters for Cmax was 102.26% (94.17-111.04%) and for AUC0-t was 101.24% (95.19-107.68%). Conclusion: Imatinib mesylate 100 mg (test product) from Eurofarma Laboratórios S.A. was considered bioequivalent to the reference Glivec® 100 mg manufactured by Novartis Biociências S.A, and the test product can be interchangeable with the reference, based on their pharmacokinetic performance


Introdução: O mesilato de imatinibe é atualmente o tratamento oral de primeira linha para todos os estágios de leucemia mieloide crônica (LMC) e é usado também em alguns casos de tumores gastrointestinais (GIST) e na leucemia linfoide aguda (LLA). Objetivo: Investigar a biodisponibilidade de dois produtos contendo mesilato de imatinibe de 100 mg em comprimidos revestidos para determinar se são bioequivalentes. Método: Estudo conduzido usando um desenho aberto, randomizado e balanceado. As formulações foram administradas de forma oral em única dose a 48 participantes saudáveis do sexo masculino após alimentação, seguido de coletas de sangue por 72 horas. Quarenta e oito participantes saudáveis foram selecionados para participar do estudo. A formulação teste da Eurofarma Laboratórios S.A. foi comparada com a formulação referência da Novartis Biociências S.A. A biodisponibilidade relativa das formulações foi avaliada em comparações estatísticas dos parâmetros farmacocinéticos relevantes obtidos de concentrações de droga das amostras coletadas mediante a utilização de um método analítico baseado em cromatografia líquida de alta performance acoplada à espectrometria de massas. Resultados: A razão das médias geométricas entre teste e referência com intervalo de confiança 90% dos parâmetros farmacocinéticos para Cmáx foi de 102,26% (94,17-111,04%) e para ASC0-t foi de 101,24% (95,19-107,68). Conclusão: Mesilato de imatinib 100 mg (produto teste) da Eurofarma Laboratórios S.A. foi considerado bioequivalente ao Glivec® 100 mg produzido por Novartis Biociências S.A., e o produto teste pode ser intercambiável como referência com base em seu desempenho farmacocinético


Introducción: El mesilato de imatinibe es actualmente el tratamiento oral de primera línea para todos los estadios de leucemia mieloide crónica (LMC) y es usado también en algunos casos de tumores gastrointestinales (GIST) y leucemia linfoide aguda (LLA). Objetivo: Investigar la biodisponibilidad de dos productos de mesilato de imatinibe de 100 mg en comprimidos revestidos para determinar si son bioequivalentes. Método: Estudio ejecutado usando un diseño abierto, aleatorizado y balanceado. Las formulaciones fueron administradas de forma oral en dosis única a 48 participantes saludables de sexo masculino en condiciones de alimentación, seguidas de muestras de sangre por 72 horas. Cuarenta y ocho participantes saludables fueron seleccionados para participar del estudio. La formulación de prueba de Eurofarma Laboratórios S.A. fue comparada con la formulación referencia de Novartis Biociências S.A. La biodisponibilidad relativa de las formulaciones fue evaluada mediante comparaciones estadísticas de los parámetros farmacocinéticos relevantes obtenidos de concentraciones del fármaco de muestras recolectadas con la utilización de un método analítico basado en cromatografía de alto rendimiento acoplada a espectrometría de masas. Resultados: La relación de las medias geométricas entre la prueba y la referencia con un intervalo de confianza del 90% de los parámetros farmacocinéticos para Cmax fue 102,26% (94,17-111,04%) y para AUC0-t fue 101,24% (95,19-107,68). Conclusión: El mesilato de imatinib 100 mg (producto de prueba) de Eurofarma Laboratórios S.A. fue considerado bioequivalente al Glivec® 100 mg producido por Novartis Biociências S.A. y el producto de prueba puede ser intercambiable con el de referencia en función de su desempeño farmacocinético


Assuntos
Humanos , Masculino , Equivalência Terapêutica , Espectrometria de Massas em Tandem , Mesilato de Imatinib , Inibidores de Proteína Tirosina Quinase
3.
Front Pediatr ; 10: 1039291, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36405845

RESUMO

Factor H (FH) is one of the most important regulatory proteins of the alternative pathway of the complement system. FH deficiency is a rare condition that causes unregulated C3 consumption, leading to an increased susceptibility to infections and glomerulopathies. Our previous studies have demonstrated a FH deficient patient carrying a c.452G > A, p.R127H FH mutation which leads to a misfolded protein and its retention in the endoplasmic reticulum. In his cultured fibroblasts, FH-delayed secretion was partially rescued when treated with curcumin, and once secreted, exhibited normal regulatory function. Here, we report a childhood-onset systemic lupus erythematosus (cSLE) in this FH deficient patient and the results of experimental treatment with curcumin aiming to rescue FH secretion and regulatory activity.

4.
Drug Des Devel Ther ; 7: 699-710, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23946646

RESUMO

BACKGROUND: Imatinib mesylate has been a breakthrough treatment for chronic myeloid leukemia. It has become the ideal tyrosine kinase inhibitor and the standard treatment for chronic-phase leukemia. Striking results have recently been reported, but intolerance to imatinib and noncompliance with treatment remain to be solved. Molecular monitoring by quantitative real-time polymerase chain reaction is the gold standard for monitoring patients, and imatinib blood levels have also become an important tool for monitoring. METHODS: A fast and cheap method was developed and validated using high-performance liquid chromatography-mass spectrometry for quantification of imatinib in human serum and tamsulosin as the internal standard. Remarkable advantages of the method includes use of serum instead of plasma, less time spent on processing and analysis, simpler procedures, and requiring reduced amounts of biological material, solvents, and reagents. Stability of the analyte was also studied. This research also intended to drive the validation scheme in clinical centers. The method was validated according to the requirements of the US Food and Drug Administration and Brazilian National Health Surveillance Agency within the range of 0.500-10.0 µg/mL with a limit of detection of 0.155 µg/mL. Stability data for the analyte are also presented. CONCLUSION: Given that the validated method has proved to be linear, accurate, precise, and robust, it is suitable for pharmacokinetic assays, such as bioavailability and bioequivalence, and is being successfully applied in routine therapeutic drug monitoring in the hospital service.


Assuntos
Antineoplásicos/sangue , Benzamidas/sangue , Cromatografia Líquida de Alta Pressão/métodos , Monitoramento de Medicamentos/métodos , Piperazinas/sangue , Inibidores de Proteínas Quinases/sangue , Pirimidinas/sangue , Benzamidas/farmacocinética , Estabilidade de Medicamentos , Humanos , Mesilato de Imatinib , Espectrometria de Massas , Piperazinas/farmacocinética , Pirimidinas/farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Rev Bras Hematol Hemoter ; 35(2): 103-8, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23741187

RESUMO

OBJECTIVE: The goal of this study was to monitor imatinib mesylate therapeutically in the Tumor Biology Laboratory, Department of Hematology and Hemotherapy, Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo (USP). A simple and sensitive method to quantify imatinib and its metabolite (CGP74588) in human serum was developed and fully validated in order to monitor treatment compliance. METHODS: The method used to quantify these compounds in serum included protein precipitation extraction followed by instrumental analysis using high performance liquid chromatography coupled with mass spectrometry. The method was validated for several parameters, including selectivity, precision, accuracy, recovery and linearity. RESULTS: The parameters evaluated during the validation stage exhibited satisfactory results based on the Food and Drug Administration and the Brazilian Health Surveillance Agency (ANVISA) guidelines for validating bioanalytical methods. These parameters also showed a linear correlation greater than 0.99 for the concentration range between 0.500 µg/mL and 10.0 µg/mL and a total analysis time of 13 minutes per sample. This study includes results (imatinib serum concentrations) for 308 samples from patients being treated with imatinib mesylate. CONCLUSION: The method developed in this study was successfully validated and is being efficiently used to measure imatinib concentrations in samples from chronic myeloid leukemia patients to check treatment compliance. The imatinib serum levels of patients achieving a major molecular response were significantly higher than those of patients who did not achieve this result. These results are thus consistent with published reports concerning other populations.

6.
Rev. bras. hematol. hemoter ; 35(2): 103-108, 2013. ilus
Artigo em Inglês | LILACS | ID: lil-676314

RESUMO

OBJECTIVE: The goal of this study was to monitor imatinib mesylate therapeutically in the Tumor Biology Laboratory, Department of Hematology and Hemotherapy, Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo (USP). A simple and sensitive method to quantify imatinib and its metabolite (CGP74588) in human serum was developed and fully validated in order to monitor treatment compliance. METHODS: The method used to quantify these compounds in serum included protein precipitation extraction followed by instrumental analysis using high performance liquid chromatography coupled with mass spectrometry. The method was validated for several parameters, including selectivity, precision, accuracy, recovery and linearity. RESULTS: The parameters evaluated during the validation stage exhibited satisfactory results based on the Food and Drug Administration and the Brazilian Health Surveillance Agency (ANVISA) guidelines for validating bioanalytical methods. These parameters also showed a linear correlation greater than 0.99 for the concentration range between 0.500 µg/mL and 10.0 µg/mL and a total analysis time of 13 minutes per sample. This study includes results (imatinib serum concentrations) for 308 samples from patients being treated with imatinib mesylate. CONCLUSION: The method developed in this study was successfully validated and is being efficiently used to measure imatinib concentrations in samples from chronic myeloid leukemia patients to check treatment compliance. The imatinib serum levels of patients achieving a major molecular response were significantly higher than those of patients who did not achieve this result. These results are thus consistent with published reports concerning other populations.


Assuntos
Humanos , Antineoplásicos/administração & dosagem , Cromatografia , Monitoramento de Medicamentos , Leucemia Mielogênica Crônica BCR-ABL Positiva , Espectrometria de Massas , Pirimidinas/administração & dosagem
7.
J Chromatogr B Analyt Technol Biomed Life Sci ; 879(31): 3728-34, 2011 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-22074958

RESUMO

In the present study a method to quantify chlorpromazine in human plasma using cyclobenzaprine as the internal standard (IS) is described. The analyte and the IS were extracted from human plasma by a liquid-liquid extraction with diethyl ether/dichloromethane (70/30, v/v) and analyzed by an ultra performance liquid chromatography (UPLC) coupled to an electrospray tandem triple quadrupole mass spectrometer in positive mode (UPLC-ES(+)-MS/MS). Chromatography was performed isocratically on an Aquity UPLC BEH C18 1.7 µm (50 mm × 2.1 mm i.d.) operating at 40°C. The mobile phase was a mixture of 65% water+1% formic acid and 35% of acetonitrile at a flow-rate of 0.5 mL/min. The lowest concentration quantified was 0.5 ng/mL and a linear calibration curve over the range 0.5-200 ng/mL was obtained, showing intra-assay precisions from 2.4 to 5.8%, and inter-assay precisions from 3.6 to 9.9%. The intra-assay accuracies ranged from 96.9 to 102.5%, while the inter-assay accuracies ranged from 94.1 to 100.3%. This analytical method was applied in a relative bioavailability study in order to compare a test chlorpromazine 100 mg simple dose formulation versus a reference in 57 volunteers of both sexes. The study was conducted in an open randomized two-period crossover design and with a fourteen days washout period. Plasma samples were obtained over a 144-h interval. Since the 90% CI for both C(max), AUC(last) and AUC(0-inf) were within the 80-125% interval proposed by the Food and Drug Administration and ANVISA, it was concluded that chlorpromazine 100 mg/dose was bioequivalent to the reference formulation, according to both the rate and extent of absorption.


Assuntos
Clorpromazina/sangue , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Adolescente , Adulto , Amitriptilina/análogos & derivados , Área Sob a Curva , Disponibilidade Biológica , Clorpromazina/farmacocinética , Estudos Cross-Over , Estabilidade de Medicamentos , Feminino , Humanos , Limite de Detecção , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Distribuição Aleatória , Reprodutibilidade dos Testes
8.
J Chromatogr B Analyt Technol Biomed Life Sci ; 877(29): 3601-9, 2009 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-19773204

RESUMO

In the present study, a novel, fast, sensitive and robust method to quantify ethinylestradiol in human plasma using 17alpha-ethinylestradiol-d4 as the internal standard (IS) is described. The analyte and the IS were extracted from acidified plasma by liquid-liquid extraction (LLE) using diethyl ether-hexane followed by online solid phase extraction (SPE) using online C18 cartridges. Extracted samples were analyzed by high-performance liquid chromatography coupled to atmospheric pressure photoionization tandem mass spectrometry (HPLC-APPI-MS/MS). Chromatography was performed isocratically on a C18, 5 microm analytical column. The method had a chromatographic run time of 2.50 min and a linear calibration curve over the range 5-500 pg ml(-1) (r(2)>0.9992). The lowest concentration quantified was 5 pg ml(-1), demonstrating acceptable accuracy and precision. The intra-assay precisions ranged from 2.1 to 14.6%, while inter-assay precisions ranged from 4.4 to 11.4%. The intra-assay accuracies ranged from 94.6 to 103.8%, while the inter-assay accuracies ranged from 98.9 to 101.6%. The recovery of ethinylestradiol was determined as part of the assay validation process and was 73.1 and 79.0% for the concentrations 15 and 375 pg ml(-1), respectively. Short-term stability showed that ethinylestradiol was stable in plasma for at least 19 h at room temperature or for at least 385 days when stored at -20 degrees C. In the study of bioequivalence conducted in Brazil, healthy volunteers received two ethinylestradiol 0.035 mg tablet formulations using an open, randomized, two-period crossover design with a 2-week washout interval. Since the 90% confidence interval for C(max) and area under the curve ratios were all inside the 80-125% interval proposed by the US Food and Drug Administration, it was concluded that the two ethinylestradiol formulations are bioequivalent with respect to both the rate and the extent of absorption.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Etinilestradiol/sangue , Etinilestradiol/farmacocinética , Espectrometria de Massas em Tandem/métodos , Humanos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...